The Model 300 Floor Sentry Double is uniquely designed to provide portable fume extraction to two operators simultaneously. Two flame-retardant, self-supportive flex arms provide equal suction at both inlets, which directs contaminants into the patented filtration system. Typical applications for this unit include soldering, welding, chemical fumes, light grinding, solvent and epoxy fume control, dust, pharmaceutical powders and many other procedures that involve the emission particulate and fume. Standard filtration options for this system include: HEPA [up to 99.97% efficient on particles 0.3 microns and larger], ASHRAE [up to 95% efficient on particles 0.5 microns and larger], Activated Carbon, and specialty-blended filter media [i.e. Acid Gas, Mercury, Aldehyde, Ammmonia]. The Floor Sentry Double allows multiple filter media to be housed inside the filter chamber for applications that emit both particulates and fumes. This unit features heavy-duty casters for easy mobility, flex arms that are capable of 360 degree rotation, and an infinitely-adjustable variable speed controller.

FILTERS INSTALLED

  • HEPA [up to 99.97% efficient on particles 0.3 microns and larger]
  • SPECIALTY-BLENDED Acid Gas FILTER MEDIA

AIR VOLUME: Variable Speed Control Standard on 115V: 175 CFM High Per Arm, Down to 50 CFM Low

SOUND LEVEL: 61 to 66 dba (Blower Speed: Low to High)

ELECTRICAL: 115/1/60, 2 amps, 8’ grounded power cord with NEMA 5-15P Plug

DIMENSIONS: 15.5” Length (Including Control Box), 13” Width, 16.5” Height; Arms: 4“ Dia., 48” Long Fire-Retardant Flex Hose

CABINET MATERIAL: 16 ga. Carbon Steel with Polyester, Epoxy Coating on all surfaces

WEIGHT: Approx. 40 - 55 lbs.

General Info

Make:Sentry Air Systems
Model:SS-300-FSD
Serial:27325N
Manual:series_300_o_m_manual.pdf
Photo:sas300.jpg&btnI=lucky


Usage

Position hose near source of fumes, turn on and rotate power switch to the desired fan speed.

Maintenance

Filter

Filter must be changed out regularly. Filter changes will vary by application and usage. WARNING BIOHAZARD: DIRTY FILTERS MAY BE CONTAMINATED. Use Personal Protective Equipment (PPE) during filter changes.

FILTER REPLACEMENT PROCEDURE:

  1. DISCONNECT POWER SUPPLY.
  2. USE PERSONAL PROTECTIVE EQUIPMENT BEFORE HANDLING FILTERS OR OTHER ITEMS THAT MAY BE CONTAMINATED.
  3. Position the fan/filter unit gently on its side.
  4. Loosen all thumb screws until the base of the screws are flush with the inside of the filter cabinet. Thumb screws must be flush with filter cabinet to avoid potential damage to the filters during removal or replacement.
  5. Always follow local and national codes for disposal.
  6. Replace filter as needed, making sure that the gasket faces toward the fan inlet.
  7. Re-tighten all thumb screws until filter gasket is sufficiently compressed to accomplish filter sealing.
  8. DO NOT over tighten.
  9. Resume normal operation.

Motor

The motors do not require significant routine maintenance. Occasionally monitor air inlet perforations, fan blades, and motor to ensure excessive particulate build up has not occurred. If there is a noticeable amount of fan vibration, inspect fan and cabinet for particulate build up. Contact factory if additional assistance is required.

Hose

Occasionally, due to over-extension the flex hose may “pop apart.” When this happens DO NOT change the diameter of the flex hose by twisting the flex at the open sections. Simply, realign open ends and snap together. Although simple, this procedure may take two operators to complete. Contact SAS for further assistance.

More Learning

Equipment Status

For availability and current status of this equipment, please see Tools Inventory, or the parent area under which this tool is maintained.

Primary Consumables

Consumable Part Number Product Link
Filter 1 SS-300-HF MODEL 300 HEPA – Up to 99.97% Efficient on particles down to .3 in size.
Filter 2 SS-310-AcidGas MODEL 300 ACID GAS FILTER – 10 lb. Heavy-Duty Acid Gas Filter
sentry_air_systems_ss300-fsd_fume_extractor.txt · Last modified: 2017/07/20 23:29 by leisa_fearing